The 11KV Medium Voltage British Standard cable is suitable for installation in power networks, underground and in cable ducting. Its low smoke zero halogen sheath makes it suitable for installations where fire, smoke emissions and toxic fumes create a potential threat.
Please note: Due to poor UV resistant qualities, red outer sheath cables are not recommended for outdoor installation.
Conductor: Stranded Plain Annealed Compacted Circular Copper Conductor
Insulation: Cross Link Polyethylene (XLPE)
Metallic Screen: Individual or overlapped copper tape screen
Bedding: Low Smoke Zero Halogen (LSZH)
Separator: Copper Binding Tape 10% Overlap
Armouring: Galvanised Steel Wire Armour
Sheath: Low Smoke Zero Halogen (LSZH)
Sheath Colour: Red or Black
Voltage Rating: 6350/11000 Volts Volts - Tested to Voltage and Duration of BS7835
Temperature Limits: -15°C to 90°C
Minimum Bending Radius: As per cable manufacturer datasheet
Core Identification: Brown, Black, Grey Tapes
Should not be installed at temperatures below 0°C or above +60°C
Maximum conductor operating temperature: 90°C
Maximum screen operating temperature: 80°C
Maximum conductor temperature during S.C: 250°C
Soil thermal resistivity: 120˚C. Cm/Watt
Burial depth: 0.5m
Ground temperature: 15°C
Air temperature: 25°C
Frequency: 50Hz
For more information please consult a member of the Cleveland Cable Sales Team
Brown Black Grey Tapes
Code | Description | Qty / Metres | |
---|---|---|---|
10302RD | 3X35,CU,XLP,CTS,LSZH,SWA,LSZH 11KV RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10304RD | 3X50,CU,XLP,CTS,LSZH,SWA,LSZH 11KV RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10306RD | 3X70,CU,XLP,CTS,LSZH,SWA,LSZH 11KV RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10308RD | 3X95,CU,XLP,CTS,LSZH,SWA,LSZH 11KV RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10310RD | 3X120,CU,XLP,CTS,LSZH,SWA,LSZH 11KV RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10312RD | 3X150,CU,XLP,CTS,LSZH,SWA,LSZH 11KV RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10314RD | 3X185,CU,XLP,CTS,LSZH,SWA,LSZH 11KVS RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10316RD | 3X240,CU,XLP,CTS,LSZH,SWA,LSZH 11KV RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10318RD | 3X300,CU,XLP,CTS,LSZH,SWA,LSZH 11KV RED BS7835, RED UV STABILISED, EASY STRIPPABLE INSULATION | ||
10320RD | 3X400 CU XLP CTS LSZH SWA LSZH 11KV RED BS7835 , RED UV STABILISED, EASY STRIPPABLE INSULATION |