Overview

Telecommunication cable, available in 0.5mm and 2, 5, 10 or 20 pairs and manufactured to ENATS 09-6. The cable features solid plain annealed copper conductors, polyethylene insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain, wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5.

The primary use of this telecommunication cable is with control indication and alarm equipment for switchgear. They are suitable for installing in circuits where the minimal voltage does not exceed ISOV DC or 11OVaC.

Standards
  • ENATS 09-6: Issue 8 Section 4.5
  • Flame propagation to:
    IEC BS4066 PT1
    IEC 332 PT1
Construction

Conductor: Solid Plain Annealed Copper Conductors
Insulation: Low Smoke Zero Halogen (LSZH)
Screen: Collective Aluminium / Mylar tape screen with 0.5mm2 drain wire
Bedding: Low Smoke Zero Halogen (LSZH)
Armouring: Galvanised Steel Wire Armour
Sheath: Low Smoke Zero Halogen (LSZH)
Sheath Colour: Black

Characteristics

Temperature limits: -30°C to +70°C
Minimum Bending Radius: As Per Manufacturers Datasheet

Should not be installed at temperatures below 0°C or above +40°C

For more information please consult a member of the Cleveland Cable Sales Team

Core IDs

See datasheet PDF for further details

**All two pair cables are in quad formation and colour coded in rotation

White Red Blue Orange

For 30 pair cables the formation will be 3 X 10 pair units numbered - 1, 2 & 3.

For 40 pair cables the formation will be 2 X 20 pair units numbered - 1 & 2.

For 50 pair cables the formation will be 5 X 10 pair units numbered - 1, 2 3, 4 & 5.

For 100 pair cables the formation will be 5 X 20 pair units numbered - 1, 2, 3, 4 & 5.

 

Products

Code Description Qty / Metres  
13601 2X2X1/0.8 (QUAD) LSZH,SCR,LSZH,SWA,LSZH,GENERALLY IN ACCORDANCE WITH ENATS-09-6 ISSUE 8 SECTION 2012. BLACK
13603 5X2X1/0.8 LSZH,SCR,LSZH,SWA,LSZH,GENERALLY IN ACCORDANCE WITH ENATS-09-6 ISSUE 8 SECTION 2012. BLACK
13604 10X2X1/0.8 LSZH,SCR,LSZH,SWA,LSZH,GENERALLY IN ACCORDANCE WITH ENATS-09-6 ISSUE 8 SECTION 2012. BLACK
13606 20X2X1/0.8 LSZH,SCR,LSZH,SWA,LSZH,GENERALLY IN ACCORDANCE WITH ENATS-09-6 ISSUE 8 SECTION 2012. BLACK